Target name in sequence not carried over from name on Framing page

Issue #1055 resolved
Carlos Taylor created an issue
  • issue is reproducible
  • running version 2.0 Beta033
  • Type in the desired target name on the Framing page and go through the ‘add target to sequence’ process and the name in the sequence is not the same

Expected behaviour

sequence target name should have same name as on Framing page

Actual behaviour

sequence target name not the same as name on Framing page

Comments (4)

  1. Stefan B repo owner

    Fix Issue #1055 - Target name in sequence not carried over from name on Framing page Furthermore remove the recenter button, as it is not really necessary and does the same as loading button.

    → <<cset 70327347b67d>>

  2. Log in to comment