- changed version to 1.7.8.6
Selected Subscription Deselections being reset on Refresh
- In Build > IC > Configure Module..., choose Selected and the check CustomObject but deselect 4 objects within it.
- Close Project Structure dialog by clicking Ok.
- Reopen Project Structure dialog (Build > IC > Configure Module).
- Click the Refresh button just above the Selected metadata tree.
- Observe the previous deselections are still intact/correct.
- Close Project Structure dialog by clicking Ok.
- Reopen Project Structure dialog (Build > IC > Configure Module).
- Observe the previous deselections have been lost.
Comments (9)
-
reporter -
Hi Scott, I see version 1.7.8.6 was just released last week. Did this issue not get resolved in that version? Would really like to see it get addressed!
-
reporter Al, I'll try to work this into the next or next-next build. If I'm unable to reproduce it using your provided steps, I'll reach out to you for more info.
-
Awesome! It's one of the last pieces of our CI puzzle! Be happy to help reproduce if you need me to.
-
reporter Okay, I reproduced this. Hopefully should be quite simple to fix at this point. I'll try to include it in the next build which I'm hoping to release tomorrow or Thursday.
-
That is fantastic news. Thanks so much for addressing this!
Al Hotchkiss Senior Salesforce Developer
[cid:image001.gif@01D01070.796B96A0] INTL FCStone Inc.
1075 Jordan Creek Parkway, Suite 300, West Des Moines, Iowa 50266 Phone: 515-223-3743 Email:al.hotchkiss@intlfcstone.com Web: www.intlfcstone.comhttp://www.intlfcstone.com/
-
reporter - changed version to 1.7.8.7
-
reporter Just submitted a fix for this.
-
reporter - changed status to resolved
Delivered in 1.7.8.7. See release notes for more information.
- Log in to comment