Firmware update/downgrade v2.5.61 asi problem

Issue #268 closed
Fer Vr created an issue

Hi guys,

Just updated my EggRider V2. And Now my e-bike 60V (non bypass) (Surron) with asi controller bac4000 will not response on the throttle.

Battery 100% and the Voltage isn’t accurate anymore. Cant calibrate the battery, fault code controller voltage overpower.

The bike has run with old eggdriver firmware. Is there a way to update it back to example the version: v2.5.61

Now i have the latest firmware but cant see the older firmwares.. Thank u guys.

Comments (7)

  1. George Banea

    Hi,

    Could you please share a picture of the display while is ON and screenshots of the settings.

    Also could you please give details of the cabling connection you did?

  2. Fer Vr reporter

    its a 60v battery (stock).

    Surron Bike

    BAC4000

    GLE HARNES

    EGGRIDER V2

    Checked all wires, cleaned them. i’ve ride a couple a days ago. Now im trying to let it work again. After the update the voltage was not accurate anymore, also get the fault message.

    Checked all wires, also the battery checked (66,2v full charge)

    Hope can back to old firmware. Have read somewhere that i need to go to the right version.

    Thank u a lot for helping.

  3. George Banea

    The Controller over Voltage (0x10 error) you are getting is coming from the controller and is due to configuration issue in the controller. It could be that you selected to update controller voltage in the ASI settings?

    Could you please try the following firmware and let us know if this fixes your issue? EggRider V2 - Beta 2.7 - v2.7.36 using the following code: 94062393-d71d-4998-adb6-9d5f01486c6f

    You can see instruction for firmware update here: https://manual.eggrider.com/firmware_update/eggrider_app/

  4. Log in to comment