simfactory's user level run command does not record jobid in a segment's properties.ini file
The (user level) run command does not record a jobid in a segment's properties.ini file which means one cannot eg restart from a checkpoint since simfactory complains about an unset jobid:
simfactory/bin/sim create-run test1 --parfile par/tov_ETK_2018_lisbon.par --procs 1 --walltime 0:5:0 & grep jobid ~/simulations/test1/output-0000/SIMFACTORY/properties.ini
shows the issue (but not producing any output). And the error obtained when trying to restart is along the lines of
Simulation name: binarybh9 Error: job id is negative Aborting Simfactory
This was reported by Qingwen Wang in http://lists.einsteintoolkit.org/pipermail/users/2018-September/006524.html
A workaround is to not use run as a user but always submit or to use the cleanup command after which simfactory is fine with there not being a job id.
Keyword: None
Comments (3)
-
-
reporter - removed comment
The issue arises b/c simfactory wants to know "is the previous job still running?" when creating a new segment to know whether it can clean up the old one and / or has to chain a new segment or not.
Making "sim run" make up its own job id is just a hack to avoid this.
-
reporter - edited description
- Log in to comment
"sim run" doesn't create a job, because it doesn't use a queueing system. It seems to me that the bug here is that resuming from a checkpoint requires a job id.