- changed title to safety buffer of 30 min for option "walltime" in submitting a ET job
- changed component to EinsteinToolkit thorn
safety buffer of 30 min for option "walltime" in submitting a ET job
Dear colleagues, During testing GW150914 I found out (and it was confrmed by Roland Haas) that the simulation stops 30 min earlier (whichis a good odea) than given by --walltime. This is a little bit surprizing if one uses (for testing) a walltime less or equal of 30 min.
Best wishes Peter Schaffarczyk, UAS Kiel, Germany
Comments (5)
-
-
This branch:
https://bitbucket.org/cactuscode/cactusutils/branch/rhaas/short_walltime
has a potential solution. It ignores
on_remaining_walltime
if at startup it is larger or equal tomax_walltime
ie when TerminationTrigger would cause the run to checkpoint right away.It does so only at startup so that steering
on_remaining_walltime
to be larger thanmax_walltime
does cause an immediate termination. -
- changed status to open
-
Will be resolved by #2450
-
- changed status to resolved
#2450has been applied, resolving this issue. - Log in to comment