1. F Malpartida
  2. CNC Controller
Issue #4 resolved

Error driving M8 threaded road with default configuration

F Malpartida
repo owner created an issue

Changing M10_200 to M8_200 in ROD_CONF_<X|Y|Z> makes the system go very slow and produces very slow movements.

Comments (2)

  1. F Malpartida reporter

    Close #4 - correct M8_200 to use floating point. When expanding the macro (X|Y|Z)_STEPS_PER_MM it was causing an overflow and the correct values were not being calculated. This is also due to the fact that the values have been scaled by 100 which make the overflow easier.

    Now the value is expanded to an float or long value.

    c9aff8580fde

  2. Log in to comment