Wiki
Clone wikiqnTools / QuNeo SysEx Rhombus Button Block
[1.2.x firmware]
There are global settings associated with the Rhombus. Global values are in the JSON as RhombusButtons→property. In the sysex, global parameters for all sensor sections are clustered together in a single QuNeo Sysex Global Block.
For the Rhombus button, the following values are added to the sysex. JSON property is in the presets file at RhombusButtons->RhombusButton0->property
Value | JSON property | Values |
---|---|---|
Enable Bank Control | rhombusEnableSwitch | 0=off, 2=on |
Bank Control (which bank) | rhombusBankControl | 0=Rotaries, 1=Vertical Sliders, 2= Long Slider, 3=Pads |
UNUSED | rhombusInNoteG | |
UNUSED | rhombusInNoteR | |
Channel | rhombusChannel | |
Note | rhombusOutNote | |
Pressure Mode | rhombusOutNotePressMode | 0=normal, 1=toggle |
Pressure CC | rhombusOutPress | -1=Off |
Pressure Value | rhombusOutPressValue | 0=Continuous |
Velocity Value | rhombusOutVelocityValue | 0=Variable |
Updated