Display of B-plane DAP and RP dose values offset in summary RF view
Issue #594
resolved
As reported by @georgstamm to the Google Group
Comments (2)
-
reporter -
reporter - changed status to resolved
Merged in issue594dualplaneRFsummaryview (pull request #161)
Fixes
#594- Dual plane systems now display properly on RF filter view→ <<cset c9789b43d633>>
- Log in to comment
Two more db queries per study, but at least it works! Issue was previous attempt to cut down as much as possible on number of queries went too far! Refs
#594→ <<cset b5504c8bb9e0>>