- marked as minor
- edited description
Improve QR logic documentation
Issue #409
resolved
Make it clear in docs what the logic is for what is retrieved.
For example, if modality CT is selected, and an SR is included as one of the series in the study, only the SR series is requested for the retrieve. If no SR is there, and series descriptions are returned, and there is a series called 'dose info', ie an older Philips, then the 'dose series' only will be requested. If there is no SR series, and no series description of 'dose series' found, then all series are requested for retrieve in case one of them is the Philips 'dose series' after all.
Comments (5)
-
reporter -
reporter - edited description
-
reporter - changed milestone to 0.7.3
-
reporter - changed milestone to 0.7.4
Not done in time. Bumping to 0.7.4
-
reporter - changed status to resolved
Fixed in issue
#506 - Log in to comment