mAs charts are displaying microAs

Issue #901 resolved
David Platten created an issue

Affects mammography scatter plot of mAs vs compressed breast thickness.

Radiographic charts are correct.

Comments (5)

  1. David Platten reporter

    Added the optional data_point_value_multipliers argument to the main mammography dataframe creation routine. This allows a scaling factor of 0.001 to be applied to the uAs values to transform them into mAs. A scaling factor is required for every value_field if this argument is being used, so added scaling factors of 1 for the other value_names that could be present. Refs issue #901

    → <<cset f5ecb7e4c893>>

  2. Log in to comment