- changed status to resolved
m/monit skew field too short
Issue #159
resolved
Hi, we are using m/monit to manage workstations and laptops, and sometimes they go "offline" for a couple of days (weekends, etc). As sometimes the "shutdown" process does not allow for monit to alert is going down (ex. suspend) it would be nice to set a bigger skew time.
But the field on m/monit only allow 3 characters...
could you please increase that field on next release?
Thanks,
Comments (3)
-
repo owner -
repo owner - removed component
Removing component: M/Monit (automated comment)
-
repo owner - removed version
Removing version: 5.12 (automated comment)
- Log in to comment
Hello,
the next M/Monit release (3.4.1) will allow up to 6 digits for report skew. The release should be available ca. within 1 week.