Player One Poseidon M stop to work (VER 2.3 RC001)

Issue #1249 closed
Massimiliano Peri created an issue

I Installed the version 2.3 RC001 to have a version fit the POA_ERROR solved. With this version, during the night (not all nights) Nina stop to download the images. The log reports, for each tentative to download the image:

----------------NINA - Nighttime Imaging 'N' Astronomy----------------

-------------------Running NINA Version 2.3.0.3001--------------------
-------------------------2023-08-25T02:12:01--------------------------
---------------------.NET Version 4.0.30319.42000---------------------
---------------------Oparating System Information---------------------
---------------------------Is 64bit OS True---------------------------
------------------------Is 64bit Process True-------------------------
---------------------------Platform Win32NT---------------------------
--------------Version Microsoft Windows NT 10.0.19044.0---------------
---------------------------Major 10 Minor 0---------------------------
----------------------------Service Pack -----------------------------

DATE|LEVEL|SOURCE|MEMBER|LINE|MESSAGE
2023-08-25T02:12:01.4289|ERROR|CameraVM.cs|Capture|761|Camera Timeout - Camera did not set image as ready after exposuretime + 60 seconds
2023-08-25T02:13:01.4459|ERROR|PlayerOneSDK.cs|GetExposure|189|PlayerOneSDK - Unexpected exception occurred during frame download!
System.Threading.Tasks.TaskCanceledException: A task was canceled.
at System.Runtime.CompilerServices.TaskAwaiter.ThrowForNonSuccess(Task task)
at System.Runtime.CompilerServices.TaskAwaiter.HandleNonSuccessAndDebuggerNotification(Task task)
at NINA.Core.Utility.CoreUtil.<Delay>d__20.MoveNext() in C:\Projects\nina\NINA.Core\Utility\CoreUtil.cs:line 124
--- End of stack trace from previous location where exception was thrown ---
at System.Runtime.ExceptionServices.ExceptionDispatchInfo.Throw()
at System.Runtime.CompilerServices.TaskAwaiter.ThrowForNonSuccess(Task task)
at System.Runtime.CompilerServices.TaskAwaiter.HandleNonSuccessAndDebuggerNotification(Task task)
at NINA.Core.Utility.CoreUtil.<Delay>d__19.MoveNext() in C:\Projects\nina\NINA.Core\Utility\CoreUtil.cs:line 118
--- End of stack trace from previous location where exception was thrown ---
at System.Runtime.ExceptionServices.ExceptionDispatchInfo.Throw()
at System.Runtime.CompilerServices.TaskAwaiter.ThrowForNonSuccess(Task task)
at NINA.Core.Utility.CoreUtil.<Wait>d__22.MoveNext() in C:\Projects\nina\NINA.Core\Utility\CoreUtil.cs:line 136
--- End of stack trace from previous location where exception was thrown ---
at System.Runtime.ExceptionServices.ExceptionDispatchInfo.Throw()
at System.Runtime.CompilerServices.TaskAwaiter.ThrowForNonSuccess(Task task)
at NINA.Equipment.SDK.CameraSDKs.PlayerOneSDK.PlayerOneSDK.<GetExposure>d__17.MoveNext() in C:\Projects\nina\NINA.Equipment\SDK\CameraSDKs\PlayerOneSDK\PlayerOneSDK.cs:line 177
2023-08-25T02:13:01.4978|ERROR|ImagingVM.cs|CaptureImage|229
NINA.Equipment.Exceptions.CameraDownloadFailedException: Camera download failed. Exposure details: Exposure time: 600, Type: LIGHT, Gain: -1, Filter:
2023-08-25T02:13:01.4988|ERROR|SequenceItem.cs|Run|233|Category: Camera, Item: TakeExposure, ExposureTime 600, Gain 125, Offset 10, ImageType LIGHT, Binning 1x1 -
System.NullReferenceException: Object reference not set to an instance of an object.
at NINA.Sequencer.SequenceItem.Imaging.TakeExposure.<Execute>d__44.MoveNext() in C:\Projects\nina\NINA.Sequencer\SequenceItem\Imaging\TakeExposure.cs:line 194
--- End of stack trace from previous location where exception was thrown ---
at System.Runtime.ExceptionServices.ExceptionDispatchInfo.Throw()
at NINA.Sequencer.SequenceItem.SequenceItem.<Run>d__66.MoveNext() in C:\Projects\nina\NINA.Sequencer\SequenceItem\SequenceItem.cs:line 224
2023-08-25T02:13:01.5038|ERROR|SequenceItem.cs|RunErrorBehavior|193|Instruction Take Exposure failed after 1 attempt. Error behavior is set to ContinueOnError. Continuing.
2023-08-25T02:13:01.5048|INFO|LoopCondition.cs|Check|75|LoopCondition finished. Iterations: 1 / 1
2023-08-25T02:13:01.5048|INFO|SequenceItem.cs|Run|224|Finishing Category: Camera, Container: NINA.Sequencer.SequenceItem.Imaging.SmartExposure, Strategy: SequentialStrategy, Items[FINISHED]: 1, Items[FAILED]: 1, Conditions: Condition: LoopCondition, Iterations: 1/1, , Triggers: Trigger: DitherAfterExposures, After Exposures: 1
2023-08-25T02:13:01.5048|INFO|MeridianFlipTrigger.cs|ShouldTrigger|261|Meridian Flip - There is still time remaining - max remaining time 01:57:38.1980000, next instruction time 600, next instruction Category: Camera, Container: NINA.Sequencer.SequenceItem.Imaging.SmartExposure, Strategy: SequentialStrategy, Items[CREATED]: 2, Conditions: Condition: LoopCondition, Iterations: 0/1, , Triggers: Trigger: DitherAfterExposures, After Exposures: 1 - and the telescope reports expected pier side pierWest. Automated Flip is not necessary.
2023-08-25T02:13:01.5048|INFO|SequenceItem.cs|Run|206|Starting Category: Camera, Container: NINA.Sequencer.SequenceItem.Imaging.SmartExposure, Strategy: SequentialStrategy, Items[CREATED]: 2, Conditions: Condition: LoopCondition, Iterations: 0/1, , Triggers: Trigger: DitherAfterExposures, After Exposures: 1
2023-08-25T02:13:01.5058|INFO|MeridianFlipTrigger.cs|ShouldTrigger|261|Meridian Flip - There is still time remaining - max remaining time 01:57:38.1980000, next instruction time 0, next instruction Category: Filter Wheel, Item: SwitchFilter, Filter: L - and the telescope reports expected pier side pierWest. Automated Flip is not necessary.
2023-08-25T02:13:01.5058|INFO|SequenceItem.cs|Run|206|Starting Category: Filter Wheel, Item: SwitchFilter, Filter: L
2023-08-25T02:13:01.5058|ERROR|AscomDevice.cs|Connected|115|PlayerOne FilterWheel 1 should be connected but reports to be disconnected. Trying to reconnect...
2023-08-25T02:13:01.5298|INFO|FailuresToTelegramTrigger.cs|WorkerFn|181|Failures to Telegram: Sending Take Exposure failed after 1 attempts!

Reasons: Object reference not set to an instance of an object.

2023-08-25T02:13:01.6467|INFO|AscomDevice.cs|Connected|122|PlayerOne FilterWheel 1 reconnection successful
2023-08-25T02:13:01.6607|INFO|SequenceItem.cs|Run|224|Finishing Category: Filter Wheel, Item: SwitchFilter, Filter: L
2023-08-25T02:13:01.6607|INFO|SequenceTrigger.cs|Run|114|Starting Trigger: RestoreGuiding
2023-08-25T02:13:01.6607|INFO|SequenceItem.cs|Run|206|Starting Category: * Instruction Set *, Container: NINA.Sequencer.Container.SequentialContainer, Strategy: SequentialStrategy, Items[CREATED]: 1
2023-08-25T02:13:01.6607|INFO|SequenceItem.cs|Run|206|Starting Category: Guider, Item: StartGuiding
2023-08-25T02:13:01.7137|INFO|PHD2Guider.cs|TryStartGuideCommand|627|Phd2 - Requesting to start guiding. Recalibrate: False
2023-08-25T02:13:01.7357|WARNING|PHD2Guider.cs|CheckPhdError|374|PHDError: all equipment must be connected first CODE: 1
2023-08-25T02:13:01.7367|ERROR|SequenceItem.cs|Run|233|Category: Guider, Item: StartGuiding -
NINA.Core.Model.SequenceEntityFailedException: Failed to start guiding
at NINA.Sequencer.SequenceItem.Guider.StartGuiding.<Execute>d__12.MoveNext() in C:\Projects\nina\NINA.Sequencer\SequenceItem\Guider\StartGuiding.cs:line 69
--- End of stack trace from previous location where exception was thrown ---
at System.Runtime.ExceptionServices.ExceptionDispatchInfo.Throw()
at NINA.Sequencer.SequenceItem.SequenceItem.<Run>d__66.MoveNext() in C:\Projects\nina\NINA.Sequencer\SequenceItem\SequenceItem.cs:line 224
2023-08-25T02:13:01.7377|ERROR|SequenceItem.cs|RunErrorBehavior|193|Instruction Start Guiding failed after 1 attempt. Error behavior is set to ContinueOnError. Continuing.
2023-08-25T02:13:01.7377|INFO|SequenceItem.cs|Run|224|Finishing Category: * Instruction Set *, Container: NINA.Sequencer.Container.SequentialContainer, Strategy: SequentialStrategy, Items[FAILED]: 1
2023-08-25T02:13:01.7387|ERROR|SequenceTrigger.cs|Run|132|Failed: Trigger: RestoreGuiding - Category: Guider, Item: StartGuiding failed to exectue
2023-08-25T02:13:01.7387|INFO|MeridianFlipTrigger.cs|ShouldTrigger|261|Meridian Flip - There is still time remaining - max remaining time 01:57:38.1980000, next instruction time 600, next instruction Category: Camera, Item: TakeExposure, ExposureTime 600, Gain 125, Offset 10, ImageType LIGHT, Binning 1x1 - and the telescope reports expected pier side pierWest. Automated Flip is not necessary.
2023-08-25T02:13:01.7387|INFO|SequenceItem.cs|Run|206|Starting Category: Camera, Item: TakeExposure, ExposureTime 600, Gain 125, Offset 10, ImageType LIGHT, Binning 1x1
2023-08-25T02:13:01.7397|INFO|CameraVM.cs|Capture|732|Starting Exposure - Exposure Time: 600s; Filter: ; Gain: 125; Offset 10; Binning: 1x1;
2023-08-25T02:13:02.2869|INFO|FailuresToTelegramTrigger.cs|WorkerFn|181|Failures to Telegram: Sending Restore Guiding failed after 0 attempts!

Reasons: Category: Guider, Item: StartGuiding failed to execute

Apparently all USB device are disconnected, If I reconnect the devices all restart to works fine. Of course normaly the issue occurs when I’m sleeping.

Thank you,

Massimiliano

Comments (1)

  1. Stefan B repo owner

    When all USB devices disconnect at the same time this is something to look at in your hardware or your windows settings. Things like USB Selective suspend and other power saving methods should be disabled in windows. In any case, not much N.I.N.A. can do here when the hardware connection gets interrupted. I recommend installing the groundstation plugin and set up push notifications in case of errors.

  2. Log in to comment