QHY367CPro Readout Mode is Blank / Error due to invalid code -1

Issue #888 resolved
Ronald Brecher created an issue

QHY367CPro connects normally, but cannot take an image. Error reported is that readout mode is invalid (-1).

This occurs with both QHY Native driver and the ASCOM driver. There is a workaround with ASCOM, but not native driver

When ASCOM is used, the Camera screen allows you to set snapshot and imaging readout modes manually, and the camera can then be used. However, readout mode defaults back to blank when camera is disconnected and reconnected (hardware and/or software disconnect/reconnect, and power off/on).

When QHY native driver is used, there is no way to set the readout mode, so the camera can’t be used at all.