assigned issue to
On SCP-220/P300 non sequential time signals do not save in program editor.
Issue #123
resolved
Example a chamber has time signals 1,2 and 9, enabling 9 in a program does not work.
A work around is to enable time signals so that it is sequential.
Comments (5)
-
-
Non sequential TS issues on P300 have been fixed and tested working. With default TS
1,2 on, turning on TS9via Setup page, program can save/load TS9 config. -
SCP220 also passed the test of modified code; TS9,10 and PTCON tested working.
-
reporter addresses
#123→ <<cset 1bb42eb91cc9>>
-
reporter - changed status to resolved
Fixed with pull request #12.
- Log in to comment