- changed status to resolved
rbend with magnetGeometryType="none" does not create whole beampipe
Issue #94
resolved
One more thing with the rbends.. it seems that when magnetGeometryType="none", the beampipe_pv is not created (only the start and end pv's), see also the screenshot. This can be replicated with the 8_magnet_none test.
Comments (2)
-
-
fix issue
#94- when magnetGeometryType="none", central piece of beam pipe in rbend wasn't built.→ <<cset 5820ca164786>>
- Log in to comment
Confirmed. Fixed with commit # 5820ca1. The test for building the central bit of beam pipe was incorrectly testing on the existence of the outer magnet geometry.