- changed status to resolved
Explain the factor 0.93 in the computation of wetbulb temperature
Issue #6
resolved
Currently, the wetbulb temperature is optimized to a slightly different formula than described in the documentation. These two should be made consistent. What is the rational of this factor?
Comments (1)
-
repo owner - Log in to comment
Factor 0.93 in wetbulb.temp documented and added to list of constants. Fixes Issue
#6. Changes do not affect results. Test for wetbulb.temp added. Email address updated.→ <<cset ed043883f4ad>>