- changed title to Problem with links from CT and radiographic chart histogram bars
- edited description
Problem with links from CT and radiographic chart histogram bars
Issue #682
resolved
If the case-insensitive chart option is selected and the user has chosen an acquisition protocol filter then the links from histogram bars don't correctly filter.
It stems from the use of __exact in mod_filters.py which needs to be replaced with __iexact
Comments (4)
-
reporter -
reporter Changed acquisition protocol filter to be case-insensitive for links from radiographic and CT histograms. References issue
#682→ <<cset e9000da00134>>
-
- changed status to resolved
Merged in issue682histogramBarLinkFailure (pull request #235)
Changed acquisition protocol filter to be case-insensitive for links from radiographic and CT histograms. Fixes issue
#682Approved-by: Ed McDonagh
→ <<cset c55c916dcdc8>>
-
- changed milestone to 0.9.0
- Log in to comment