Refs #491 Add extraction of the dose check details for CT

#73 Merged at 14ca8d4
Repository
LuukO
Branch
issue491ExtractDoseCheckDetails
Repository
openrem
Branch
issue491ExtractDoseCheckDetails
Author
  1. Luuk
Reviewers
Description

Implemented extraction of dose check details. Partly tested as no RDSR available with 'reason for proceeding' and/or 'forward estimates'

Code Quality

Comments (4)

  1. Ed McDonagh

    Hi @LuukO, thanks for this. Can you change the merge from develop to issue491ExtractDoseCheckDetails so that I can play with it and run the tests etc?

    What examples do you have with dose check details in?

    (And sorry for the delay!)

  2. Luuk author

    Hi @edmcdonagh, I've got rdsrs with CTDIvol alert value. So it is only partially tested. Actually I can create quite easily an RDSR with DLP alert value and the notification values also (just a small change at the CT scanner settings to get it). It would take some time to set these values (very) low, so I can also get an RDSR with "reason for proceeding" also (Can't be done during working hours, of course). So if they are not at hand at your site, I'm willing to create such an RDSR.

  3. Ed McDonagh

    I'm on leave this week, so if you get s chance that would be great. Otherwise, I'll have to try when I'm back at work.

  4. Ed McDonagh

    Hi @LuukO. Can you switch the destination please so I can test it within this repo before merging to develop? Thanks