Smart Sequence Dither failing
Which Version are you running?
2.1
Description
Blinking the previous mights images I see most are not dithered. I look at the PHD2 logs and saw large gaps in the dither commands. I was running a Smart Sequence of 120 x 300s subs and with dither set to 1; after every image.
Steps to Reproduce
In the attached log you will find the last correct dither:
23:09:54.3059 - Finishing Category: Camera, Item: TakeExposure
23:09:54.4469 - Starting Trigger: DitherAfterExposures, After Exposures: 1
23:09:54.4469 - Starting Category: Guider, Item: Dither
23:10:11.9767 - Finishing Category: Guider, Item: Dither
The next image at has no dither following it:
23:10:12.0467 - Starting Category: Camera, Item: TakeExposure
23:15:13.1279 - Finishing Category: Camera, Item: TakeExposure
There is no dither until the next one over four hours later, all while running the same sequence.
03:54:36.2715 - Starting Trigger: DitherAfterExposures, After Exposures: 1
Expected behaviour
Should dither after every sub.
Actual behaviour
Gave up on dithering at some point during the sequence after first dithering correctly. Over 50 subs without dither.
Comments (3)
-
repo owner -
repo owner - changed status to resolved
Fix Issue
#1185- Dither after exposures will no longer fail when clearing the image history→ <<cset ebbf6286b099>>
-
repo owner Fix Issue
#1185- Dither after exposures will no longer fail when clearing the image history→ <<cset ee859ba8457b>>
- Log in to comment
Did you clear the image history in between? I just realized that this leads to such a scenario. Will fix that.