- edited description
HFR shows different values when star detection and analysis is on vs off using OSC cameras
Running 1.11#013
Description
Reported HFR has a large difference depending on if auto star detection is turned on or off in the Imaging->Image tab. When star detection is turned off HFR is reported as much higher than when it is turned on.
Steps to Reproduce
- Be running a sequence with auto star detection off
- Allow several images to be acquired
- Turn auto star detection on
- Allow several more images to be acquired
Expected behaviour
HFR report is similar if auto star detection is on or off (assuming no change in conditions)
Actual behaviour
Images acquired with star detection off report a much higher HFR
Comments (13)
-
reporter -
reporter - attached nina-013_hfr.log
-
repo owner At least using the simulator i am not able to reproduce it…
-
reporter It’s possible that it only shows up when using a DSLR (Nikon?) camera. I tried to use the simulator or file cameras, but NINA says “Unsupported CFA/Bayer pattern: Monochrome” with either of them when loading my images to try and reproduce (Nightly
#021). Also note that the file camera reports Sensor Type Monochrome in the Equipment->Camera tab even when Is Bayered is turned on in settings. -
repo owner Does it still happen with the latest nightly? A couple of things have been reworked with the Image history
-
reporter Something similar is still happening with Nightly 053
-
reporter - attached 5aMNoAS.png
<div class="preview-container wiki-content"><!-- loaded via ajax --></div> <div class="mask"></div> </div>
</div> </form>
-
reporter I recently got a dedicated astro camera instead of the Nikon that I was using at the time of reporting this. I cannot reproduce it using the new camera (ZWO ASI2600MM). Maybe this helps with isolating the issue.
-
repo owner Ok thank you for the update. That would narrow down things, as i wasn’t able to reproduce it anywhere (and i don’t own a nikon cam)
-
repo owner - changed title to HFR shows different values when star detection and analysis is on vs off using Nikon cameras
-
repo owner - changed title to HFR shows different values when star detection and analysis is on vs off using OSC cameras
This issue seems to be linked to the “Unlinked HFR” setting and OSC images. My guess at the moment is that the order of post processing is different in the two scenarios
-
repo owner - changed status to resolved
Issue found and resolved in 1.11 Nightly 146
-
repo owner - removed version
Removing version: 1.11 Nightly (automated comment)
- Log in to comment